Add to Cart
UPS 1KW 1KVA Online UPS true online ups computer ups online ups double conversion LCD
Features:
Description:
The CK Series is a high-performance single phase online double conversion UPS system, offering capacities from 1kVA to 10kVA. Utilizing advanced three-level topology and soft-switching technology, it incorporates Active Power Factor Correction (APFC) for input PFC values up to 0.99. Its compact, high energy density design significantly reduces footprint, optimizing space usage in server rooms. Compatible with generators, it offers full digital control, robust fault diagnostics, and protection from voltage sags, surges, frequency deviations, harmonics, and EMI/RFI interference—ensuring high power quality for critical loads.
Specifications:
Model | C1K | C2K | C3K | C6K | C10K | ||
Rated Power | 1000W | 2000W | 3000W | 6KW | 10KW | ||
Display | LCD | ||||||
INPUT | |||||||
Input Formats | L+N+PE | ||||||
Rated Input Voltage | 208/220/230/240VAC | ||||||
Voltage Range | 110~300VAC ( 110~176VAC,280~300VAC power limited ) | ||||||
Frequency Range | 50/60Hz±6Hz,± 10Hz (setable) | ||||||
Input Power Factor | ≥0.99 | ||||||
OUTPUT | |||||||
Output Formats | L+N+PE | ||||||
Output voltage | 208/220/230/240VAC | ||||||
Output Accuracy | ±1% | ||||||
Frequency | AC mode: same as AC ,Battery mode:50/60Hz±1% | ||||||
Harmonic Distortion | ≦1% THD(linear load), ≦3% THD(non-linear load) | ≦2% THD(linear load), ≦5% THD(non-linear load) | |||||
Wave form | Sine Wave | ||||||
Output Power Factor | 1.0 | ||||||
Transform Time | AC mode to Batt. Mode:0ms,Inverter mode to Bypass mode:4ms | ||||||
Load Capacity | AC Mode: 30min@102%~110% Load 10min@110%~130% Load 30s@130%~150% Load 200ms@>150% Load | Battery Mode: 1min@102%~110% Load 10s@110%~130% Load 3s@130%~150% Load 200ms@>150% Load | AC Mode: 30min@102%~110% Load 10min@110%~130% Load 30s@130%~150% Load 500ms@>150% Load | Battery Mode: 10min@102%~110% Load 1min@110%~130% Load 10s@130%~150% Load 500ms@>150% Load | |||
EFFICIENCY | |||||||
AC Mode | Peak efficiency 94.5% | Peak efficiency 94.5% | Peak efficiency 94% | Peak efficiency 95.5% | |||
Full load efficiency 90% | Full load efficiency 91% | Full load efficiency 91% | Full load efficiency 95% | ||||
BATTERY | |||||||
QTY & capacity of battery | Built-in: 2pcs*12V7Ah | Built-in: 4/6pcs*12V7Ah | Built-in: 6pcs*12V7Ah | Built-in: 16-20pcs*12V7Ah | Built-in: 16-20pcs*12V7Ah | ||
External battery norminal DC voltage | ------- | ------- | ------- | ------- | ------- | ||
Charging Current | Standard type: 1A, Long backup type KS: 1A~12A(adjustable by user) | ||||||
WORKING ENVIRONMENT | |||||||
Ambient Temperature | 0~40℃ | ||||||
Ambient Humidity | 20%~95%(No Condensation) | ||||||
Storage Temperature | -15~60℃(Battery:0~40℃) | ||||||
Altitude | <1000m,Derating at above 1000m,maximum 4000m,Refer to IEC62040 | ||||||
COMUNICATION INTERFACE | |||||||
Interface | RS232, USB, EPO, Manual Maintenance bypass, SNMP slot selectable (Optional, refer to customers' requires) | ||||||
PHYSICAL | |||||||
Unit dimension (mm) | 347*145*225 | 395*190*325 | 395*190*325 | 460*200*720 | 460*200*720 | ||
Net weight | 17.5 | 24 | 24.2 | 61 | 61.5 |
1KVA Rear Panel:
Supports multiple international socket standards such as Schuko (EU), US, Universal, IEC, NEMA, UK, and Brazilian,etc
Applications:
Ideal for deployment in data centers, server rooms, and across industries such as telecommunications, finance, government, energy, and manufacturing.
FAQ: