Industrial Online UPS 120KVA Low Frequency Online UPS Transformer base 3 Phase Double conversion, Transformer base
RSUN DP33 Series offers reliable power backup for sensitive industrial and data center operations, with capacity options from 10kVA to 200kVA. Engineered with double-conversion technology, it provides uninterrupted, clean sine wave output during power failures.
The UPS is built with high-speed DSP control and a full digital microcontroller system, enhancing energy conversion, load response, and fault detection accuracy. It maintains consistent voltage and frequency even under poor grid conditions.
Supporting multiple communication interfaces, RS232, SNMP, GPRS, it allows centralized monitoring and control across distributed sites. Scalable, compact, and intelligent, the DP33 is well-suited for mission-critical infrastructure.
FEATURES:
SPECIFICATIONS:
Model | 6KVA | 10KVA | 15KVA | 20KVA | 30KVA | 40KVA | 60KVA | 80KVA | 100KVA | 120KVA | 160KVA | 200KVA |
INPUT | ||||||||||||
Voltage | (208/308/400/480Vac) ± 20% / 5 wires (3 lines + neutral + ground) | |||||||||||
Frequency | 50/60Hz ± 10% Auto sensing | |||||||||||
Power factor | 0.8 | |||||||||||
Filter | EMI, RFI | |||||||||||
Dual input | optional | |||||||||||
OUTPUT | ||||||||||||
Voltage | (208/308/400/480Vac) ± 20% / 5 wires (3 lines + neutral + ground) | |||||||||||
Frequency | 50/60Hz ± 1% Auto sensing | |||||||||||
Power factor | 0.8 | |||||||||||
Crest factor | 3:1 | |||||||||||
Voltage T.H.D. | <2% with linear load | |||||||||||
Efficiency | AC/AC>92% | |||||||||||
Transfer time | 0 ms | |||||||||||
Wave form | sine wave | |||||||||||
Technology | true on-line double conversion controlled by microcontroller | |||||||||||
Overload recovery | automatically transfer to UPS mode | |||||||||||
Lsolation transformer | inverter mode (bypass mode is optional) | |||||||||||
Parallel connection | parallel connection function is ready (extra PCB is not reuired) | |||||||||||
BATTERY | ||||||||||||
Battery type | VRLA (valve regulated lead acid), not included | |||||||||||
DC voltage | 384 Vdc | |||||||||||
Charging time | 4 hours up to 90% | |||||||||||
Battery detection | self-detect, transfer to battery mode adjustable | |||||||||||
PROTECTION | ||||||||||||
Lightning and transient protection | hot swappable lightning and transient surge suppressor (in:10Kamp, Up:1.5 Kv, I max: 20 Kamp.) | |||||||||||
Harware protection | input breaker, output breaker, battery breaker, bypass breaker; DC fuse, fan, redundant power supply; temperature sensor, EPO (Emergency Power Off), audible alarms etc. | |||||||||||
Software protection | discharging batteries, battery charger working mode, inverter working mode, emergency power off, manual shutdown, bypass SCR failure, bypass sequence failure, bypass over the limit, critical overload, batteries exhaustion, low or high output voltage, DC fuse open, 5V power supply failure, 13.5 power supply failure, inverter overvoltage, 200% overload on each line, transfer failure, inverter voltage out of range, over voltage betweenneutral and ground, UPS on bypass mode, bypass frequency out of range. | |||||||||||
Bypass | solid state | |||||||||||
Communication | RS232 intelligent slot, modem, SNMP(RJ45) (SNMP adaptive software is supplied by the producer) |
Advanced communication function:
This UPS supports real-time system monitoring via RS232, GPRS, or network interfaces. With optional SNMP card integration, it enables seamless remote access over TCP / IP, SNMP, and HTTP protocols, compatible with all major operating systems. This facilitates centralized power management, remote diagnostics, and system maintenance, even across geographically distributed sites.