Add to Cart
Medical Online Transformer Based UPS 200KVA Low Frequency Online UPS Three Phase 160KW
The RSUN DP33 Series is a robust three-phase online UPS, ranging from 10kVA to 200kVA, built on true double-conversion technology for continuous sine wave power without transfer time. Its DSP and microcontroller-based control ensures precise voltage and frequency regulation, fault isolation, and high conversion efficiency under harsh grid conditions.
Ideal for industrial and IT environments, it features RS232, SNMP, and GPRS communication for real-time remote monitoring and diagnostics. Its scalable tower design supports deployment in mission-critical systems requiring stable and reliable power.
FEATURES:
SPECIFICATIONS:
Model | 6KVA | 10KVA | 15KVA | 20KVA | 30KVA | 40KVA | 60KVA | 80KVA | 100KVA | 120KVA | 160KVA | 200KVA |
INPUT | ||||||||||||
Voltage | (208/308/400/480Vac) ± 20% / 5 wires (3 lines + neutral + ground) | |||||||||||
Frequency | 50/60Hz ± 10% Auto sensing | |||||||||||
Power factor | 0.8 | |||||||||||
Filter | EMI, RFI | |||||||||||
Dual input | optional | |||||||||||
OUTPUT | ||||||||||||
Voltage | (208/308/400/480Vac) ± 20% / 5 wires (3 lines + neutral + ground) | |||||||||||
Frequency | 50/60Hz ± 1% Auto sensing | |||||||||||
Power factor | 0.8 | |||||||||||
Crest factor | 3:1 | |||||||||||
Voltage T.H.D. | <2% with linear load | |||||||||||
Efficiency | AC/AC>92% | |||||||||||
Transfer time | 0 ms | |||||||||||
Wave form | sine wave | |||||||||||
Technology | true on-line double conversion controlled by microcontroller | |||||||||||
Overload recovery | automatically transfer to UPS mode | |||||||||||
Lsolation transformer | inverter mode (bypass mode is optional) | |||||||||||
Parallel connection | parallel connection function is ready (extra PCB is not reuired) | |||||||||||
BATTERY | ||||||||||||
Battery type | VRLA (valve regulated lead acid), not included | |||||||||||
DC voltage | 384 Vdc | |||||||||||
Charging time | 4 hours up to 90% | |||||||||||
Battery detection | self-detect, transfer to battery mode adjustable | |||||||||||
PROTECTION | ||||||||||||
Lightning and transient protection | hot swappable lightning and transient surge suppressor (in:10Kamp, Up:1.5 Kv, I max: 20 Kamp.) | |||||||||||
Harware protection | input breaker, output breaker, battery breaker, bypass breaker; DC fuse, fan, redundant power supply; temperature sensor, EPO (Emergency Power Off), audible alarms etc. | |||||||||||
Software protection | discharging batteries, battery charger working mode, inverter working mode, emergency power off, manual shutdown, bypass SCR failure, bypass sequence failure, bypass over the limit, critical overload, batteries exhaustion, low or high output voltage, DC fuse open, 5V power supply failure, 13.5 power supply failure, inverter overvoltage, 200% overload on each line, transfer failure, inverter voltage out of range, over voltage betweenneutral and ground, UPS on bypass mode, bypass frequency out of range. | |||||||||||
Bypass | solid state | |||||||||||
Communication | RS232 intelligent slot, modem, SNMP(RJ45) (SNMP adaptive software is supplied by the producer) |
Advanced communication function:
Advanced Communication Capabilities
The UPS supports local and remote monitoring via RS232, SNMP, and GPRS. With the optional SNMP card, users can manage power systems over TCP/IP, SNMP, or HTTP protocols, regardless of operating system. Centralized monitoring across multiple locations is easily achieved, enabling real-time status tracking, remote diagnostics, and global power infrastructure management.
APPLICATIONS: