Add to Cart
Modular UPS System 50K - 1200KVA Ups 1000kva 10.4 Inch Touch Screen 50 / 60 kVA Power module, 50kVA / 60kVA UPS Power Module, Double DSP control
Modular, hot-swappable, field-replaceable STS, Monitor, UPS module
The RSUN PM Series modular UPS is engineered for enterprise-grade continuity. Powered by dual-DSP controllers, it delivers reliable online double-conversion, regulating power with high precision and real-time diagnostics.
Its modular, hot-swappable design allows flexible capacity (scalable from base to 300 kVA+) and built-in redundancy. With intelligent power sharing, distributed logic, and a three-level inverter, it ensures optimal efficiency and system fault resilience.
Perfect for data-critical industries, it supports rapid maintenance (low MTTR) and long-term operational savings.
FEATURES:
SPECIFICATIONS:
Model | PM200 | PM300 | PM500 | PM600 | PM840 | PM1000 |
System Capacity | 200kVA | 300kVA | 500kVA | 600kVA | 840kVA/840kW | 1000kVA/1000kVA |
Power Module Capacity | 50kVA | 50kVA | 50kVA | 50kVA | 60kVA/60kW | 62.5kVA/62.5kW |
No. of Modules | 4 | 6 | 10 | 12 | 14 | 16 |
Main | ||||||
Input Wiring | 3Ph+N+PE | |||||
Rated Voltage | 380/400/415VAC (line-line) | |||||
Input Power Factor | >0.99 | |||||
Total Harmonic Distortion | THDi<3% for linear full load, THDi<5% for nonlinear full load | |||||
Voltage Range | 304~478Vac(line-line) 100% load; | |||||
228V~304Vac (line-line) load derated from 100%-75% linearly | ||||||
Input Frequency | 40Hz~70Hz | |||||
Bypass | ||||||
Rated Voltage | 380/400/415VAC (line-line) | |||||
Voltage Range | Default Range +15%~-20%(+10%,+15%,+20%,+25%, +25%-10%,-15%, -20%, -30%,-40% can be set) | |||||
Input Frequency | ±1Hz,±3Hz,±5Hz can be set | |||||
Battery | ||||||
Input Voltage | ±240VDC (the number of batteries can be selected from 30 to 44) | |||||
Charging Power | 20% * Power Module | |||||
Charging voltage accuracy | ±1% | |||||
Output | ||||||
Rated Voltage | 380/400/415VAC (line-line) | |||||
Rated Frequency | 50/60Hz | |||||
Power Factor | 1 | |||||
Voltage Accuracy | ≤±1.0%@Steady ;≤±5.0%@ Transient | |||||
Dynamic response | <5% (20% - 80% -20% Step load) | |||||
Dynamic recovery time | < 20ms (0% - 100% -0% Step load) | |||||
THDu | THDu <1%(linear load),THDu<5%( non linear load), | |||||
Overload Capacity | 110% overload for 60 min; 125% overload for 10 min; 150% overload for 1 mins; | |||||
>150% overload for 200ms | ||||||
System | ||||||
Efficiency | >96.5% (Dual Switch mode) | |||||
Display | 10.4 inch Touch Screen+LCD+LED | |||||
IP | IP20 | |||||
Environment | Operating Temperature: 0-40℃;Relative Humidity 0-95%(No condensing) | |||||
Noise | <55dB@1 meter away | |||||
Dimension ( WxDxH mm) and Weight (kg) | ||||||
Cabinet Dimension | 600*850*2000 | 600*1100*2000 | 1000*1000*2000 | 1000*1000*2000 | 1800*850*2000 | 3600*1000*2000 |
Module Dimension | 440*720*130 (3U) | 440*720*174 (4U) | ||||
Cabinet Weight (KG) | 190 | 270 | 450 | 530 | 960 | 1100 |
Module Weight (KG) | 39 | 39 | 39 | 39 | 39 | 39 |
APPLICATIONS:
Engineered for high-reliability power protection, this system supports critical applications across:
• Large-scale and modular data centers, ISP nodes, and IT hosting environments
• National and regional telecom carriers, signal relay hubs, and 5G infrastructure
• Core financial networks, real-time transaction processing, and digital banking
• Government platforms requiring 24/7 uptime and data integrity assurance
• Healthcare facilities: ICU equipment, medical record systems, diagnostics imaging
• Industrial control systems, production automation lines, and distributed PLCs
• Precision electronics and lab-grade equipment requiring ultra-clean power