Modular UPS System 200KVA UPS 200KW 3U 50Kva power modules N +X Full DSP Control
50kVA 60kVA UPS Power Module, Double DSP control
Scalable from 50 kVA to 1200kVA.
Modular, hot-swappable, field-replaceable STS, Monitor, UPS module
RSUN PM Series is a cutting-edge modular UPS designed for scalable, high-reliability power protection. Its architecture integrates dual high-speed DSPs, achieving seamless double-conversion with intelligent control across rectifier, charger, and inverter stages.
Featuring advanced current-sharing logic, synchronized master-slave modules, and multi-level distributed control, the system supports hot-swappable modules, redundancy (N+X), and three-level inverter topology for outstanding efficiency and low THDi.
Ideal for data centers, finance, and industrial automation, the PM Series ensures minimized downtime, flexible capacity scaling, and reduced total cost of ownership.
FEATURES:
SPECIFICATIONS:
Model | PM200 | PM300 | PM500 | PM600 | PM840 | PM1000 |
System Capacity | 200kVA | 300kVA | 500kVA | 600kVA | 840kVA/840kW | 1000kVA/1000kVA |
Power Module Capacity | 50kVA | 50kVA | 50kVA | 50kVA | 60kVA/60kW | 62.5kVA/62.5kW |
No. of Modules | 4 | 6 | 10 | 12 | 14 | 16 |
Main | ||||||
Input Wiring | 3Ph+N+PE | |||||
Rated Voltage | 380/400/415VAC (line-line) | |||||
Input Power Factor | >0.99 | |||||
Total Harmonic Distortion | THDi<3% for linear full load, THDi<5% for nonlinear full load | |||||
Voltage Range | 304~478Vac(line-line) 100% load; | |||||
228V~304Vac (line-line) load derated from 100%-75% linearly | ||||||
Input Frequency | 40Hz~70Hz | |||||
Bypass | ||||||
Rated Voltage | 380/400/415VAC (line-line) | |||||
Voltage Range | Default Range +15%~-20%(+10%,+15%,+20%,+25%, +25%-10%,-15%, -20%, -30%,-40% can be set) | |||||
Input Frequency | ±1Hz,±3Hz,±5Hz can be set | |||||
Battery | ||||||
Input Voltage | ±240VDC (the number of batteries can be selected from 30 to 44) | |||||
Charging Power | 20% * Power Module | |||||
Charging voltage accuracy | ±1% | |||||
Output | ||||||
Rated Voltage | 380/400/415VAC (line-line) | |||||
Rated Frequency | 50/60Hz | |||||
Power Factor | 1 | |||||
Voltage Accuracy | ≤±1.0%@Steady ;≤±5.0%@ Transient | |||||
Dynamic response | <5% (20% - 80% -20% Step load) | |||||
Dynamic recovery time | < 20ms (0% - 100% -0% Step load) | |||||
THDu | THDu <1%(linear load),THDu<5%( non linear load), | |||||
Overload Capacity | 110% overload for 60 min; 125% overload for 10 min; 150% overload for 1 mins; | |||||
>150% overload for 200ms | ||||||
System | ||||||
Efficiency | >96.5% (Dual Switch mode) | |||||
Display | 10.4 inch Touch Screen+LCD+LED | |||||
IP | IP20 | |||||
Environment | Operating Temperature: 0-40℃;Relative Humidity 0-95%(No condensing) | |||||
Noise | <55dB@1 meter away | |||||
Dimension ( WxDxH mm) and Weight (kg) | ||||||
Cabinet Dimension | 600*850*2000 | 600*1100*2000 | 1000*1000*2000 | 1000*1000*2000 | 1800*850*2000 | 3600*1000*2000 |
Module Dimension | 440*720*130 (3U) | 440*720*174 (4U) | ||||
Cabinet Weight (KG) | 190 | 270 | 450 | 530 | 960 | 1100 |
Module Weight (KG) | 39 | 39 | 39 | 39 | 39 | 39 |
APPLICATIONS:
This UPS system is purpose-built for environments where continuous, clean power is mission-critical, including:
• Internet Data Centers (IDCs), cloud service clusters, and edge computing nodes
• Telecommunications infrastructure: core routing, base stations, and ISP operations
• Financial data hubs, banking systems, trading platforms, and securities processing
• Public sector and e-Government platforms: taxation, registries, and secure communication
• Medical IT networks, hospital imaging systems, and laboratory diagnostics
• Factory automation, SCADA systems, robotics, and smart industrial controls
• High-precision instrumentation, testing rigs, and R&D electronics labs