Modular UPS Systems 60K - 300KVA With 20kVA 25kVa Power Module 60 Kva UPS Three phase, 25kVA 50kVA UPS Power Module, Double DSP control
Scalable from 60 kVA to 1200kVA.
Modular, hot-swappable, field-replaceable STS, Monitor, UPS module
The RSUN PM Series is a modular online double-conversion UPS built for high-demand environments. Utilizing dual high-speed DSPs and three-level inverter architecture, it delivers precise control, high power density, and advanced system protection.
Its modular structure supports seamless capacity expansion and N+X redundancy, ensuring continuous uptime and adaptability. Smart current-sharing, distributed control, and hot-swappable modules reduce maintenance time and improve system resilience.
Ideal for data centers, telecom, and industrial control, the PM Series offers high availability, efficient load handling, and a lower total cost of ownership.
FEATURES:
SPECIFICATIONS:
Model | PM60 | PM120 | PM200 | PM300 | |
Rated Capacity | 60kVA | 120kVA | 200kVA | 300kVA | |
INPUT | |||||
Wiring Method | 3 Phase+N+PE | ||||
Rated Voltage | 380/400/415VAC(line-line) | ||||
Rated Frequency | 50/60Hz | ||||
Voltage Range | 304VAC ~ 478VAC (line-line) full load, 304VAC ~ 228VAC (line-line) Load derating linearly from 100% to 80% | ||||
Frequency Range | 40Hz~70Hz | ||||
Power Factor | >0.99 | ||||
THD | THD<3%(linear full load), THD<5%(non-linear full load) | ||||
BYPASS | |||||
Rated Voltage | 380/400/415VAC(line voltage) | ||||
Voltage Range | Factory setting -20% ~ +15%, settable, upper limit:+10%, +15%,+20%,+25%, lower limit:-10%,-15%, -20%, -30%,-40% | ||||
Frequency Range | Rated frequency 50/60Hz, frequency range can be set ±1Hz ,±3Hz ,±5Hz | ||||
Overload Capacity | 110% for long run, >150% for 200ms | ||||
BATTERY | |||||
Battery Voltage | ±192VDC ( 360 ~ 528VDC, 30 ~ 44 block settable, factory setting 32 block) | ||||
Charging Capacity | 15%* total capacity | ||||
Voltage Accuracy | ±1% | ||||
OUTPUT | |||||
Rated Voltage | 380V/400V/415V(line-line) | ||||
Rated Frequency | 50/60Hz | ||||
Power Factor | 1 | ||||
Voltage Accuracy | ≤±1.0%@ balanced load, ≤±5.0%@ unbalanced load | ||||
Frequency Accuracy | 50/60Hz±0.01% | ||||
Frequency Tracking Range | Settable, ±0.5Hz~±5Hz, factory setting ±3Hz | ||||
THD | THDu≤2%(100% linear load), THDu≤4%( nonlinear load) | ||||
Three-phase Phase Accuracy | 120°±1° | ||||
Crest Factor | 3:01 | ||||
Overload |
<105% long run, <110% 60mins, 110 ~ 125% 10mins, >125 ~ 150% 1mins, >150% 200ms |
||||
SYSTEM | |||||
System Efficiency | ≥96%@ double conversion mode ,≥98%@ECO mode | ||||
Display | Touch screen + LED | ||||
Wiring | Support top in and bottom in | Top in | |||
Standard | IEC62040-1-1; IEC62040-2; IEC62040-3 | ||||
Protection Class | IP20 | ||||
Feeder Protection | Standard: isolating switch, optional: fuse | ||||
Communication | RS232/ RS485/ Modbus/SNMP (optional) / dry contact (optional) | ||||
Optional | Dust-proof net, lightning protection module, LBS cable, earthquake-proof components, temperature and humidity sensor | ||||
Working Condition | Temperature :0 ~ 40℃, humidity:0~95%( no condensation) | ||||
Noise | <60dB@1 meter | ||||
Altitude | <1000 meters, no derating, >1000 meters, derating 1% if every 100 meters increased | ||||
Cabinet Type | 4 Modules | 7 Modules | 12 Modules | ||
SIZE | |||||
System W x D x H (mm) | 600 x 890 x 1200 | 600 x 960x 1600 | 600 x 1010 x 2000 | ||
Module W x D x H (mm) | 440 x 690 x 86 ( 2U) | ||||
WEIGHT | |||||
System(kg) | 140 | 185 | 250 | 270 | |
Module(kg) | 25 |
APPLICATIONS:
• Data centers & edge computing
• Telecom and ISP nodes
• Banking, finance & taxation systems
• Medical IT & hospital networks
• Industrial automation and precision electronics