Add to Cart
Power Modules 20kVA 25kVA 2U Modular UPS System Double conversion, Modular design
20kVA 25kVA 50kVA 60kVA UPS Power Modules, Double DSP control
Scalable from 20 kVA to 300kVA.
Modular, hot-swappable, field-replaceable STS, Monitor, UPS module
The RSUN PM Series delivers a new standard in modular UPS performance, combining true online double-conversion topology with a dual high-speed DSP core for precise control and fault isolation.
Its modular architecture enables seamless capacity upgrades and N+X redundancy, supporting scalable configurations from medium-sized deployments to large mission-critical facilities. With advanced rectifier sharing, synchronized module management, and three-level inverter design, the system achieves excellent energy efficiency and load stability.
Built for 24/7 operations in data infrastructure, industrial automation, and high-availability environments, the PM Series minimizes downtime, streamlines maintenance, and ensures continuous power protection even under dynamic load conditions.
FEATURES:
1. Up to 96% system efficiency, minimizing energy and cooling costs.
SPECIFICATIONS:
Model | PM60 | PM120 | PM200 | PM300 | |
Rated Capacity | 60kVA | 120kVA | 200kVA | 300kVA | |
INPUT | |||||
Wiring Method | 3 Phase+N+PE | ||||
Rated Voltage | 380/400/415VAC(line-line) | ||||
Rated Frequency | 50/60Hz | ||||
Voltage Range | 304VAC ~ 478VAC (line-line) full load, 304VAC ~ 228VAC (line-line) Load derating linearly from 100% to 80% | ||||
Frequency Range | 40Hz~70Hz | ||||
Power Factor | >0.99 | ||||
THD | THD<3%(linear full load), THD<5%(non-linear full load) | ||||
BYPASS | |||||
Rated Voltage | 380/400/415VAC(line voltage) | ||||
Voltage Range | Factory setting -20% ~ +15%, settable, upper limit:+10%, +15%,+20%,+25%, lower limit:-10%,-15%, -20%, -30%,-40% | ||||
Frequency Range | Rated frequency 50/60Hz, frequency range can be set ±1Hz ,±3Hz ,±5Hz | ||||
Overload Capacity | 110% for long run, >150% for 200ms | ||||
BATTERY | |||||
Battery Voltage | ±192VDC ( 360 ~ 528VDC, 30 ~ 44 block settable, factory setting 32 block) | ||||
Charging Capacity | 15%* total capacity | ||||
Voltage Accuracy | ±1% | ||||
OUTPUT | |||||
Rated Voltage | 380V/400V/415V(line-line) | ||||
Rated Frequency | 50/60Hz | ||||
Power Factor | 1 | ||||
Voltage Accuracy | ≤±1.0%@ balanced load, ≤±5.0%@ unbalanced load | ||||
Frequency Accuracy | 50/60Hz±0.01% | ||||
Frequency Tracking Range | Settable, ±0.5Hz~±5Hz, factory setting ±3Hz | ||||
THD | THDu≤2%(100% linear load), THDu≤4%( nonlinear load) | ||||
Three-phase Phase Accuracy | 120°±1° | ||||
Crest Factor | 3:01 | ||||
Overload |
<105% long run, <110% 60mins, 110 ~ 125% 10mins, >125 ~ 150% 1mins, >150% 200ms |
||||
SYSTEM | |||||
System Efficiency | ≥96%@ double conversion mode ,≥98%@ECO mode | ||||
Display | Touch screen + LED | ||||
Wiring | Support top in and bottom in | Top in | |||
Standard | IEC62040-1-1; IEC62040-2; IEC62040-3 | ||||
Protection Class | IP20 | ||||
Feeder Protection | Standard: isolating switch, optional: fuse | ||||
Communication | RS232/ RS485/ Modbus/SNMP (optional) / dry contact (optional) | ||||
Optional | Dust-proof net, lightning protection module, LBS cable, earthquake-proof components, temperature and humidity sensor | ||||
Working Condition | Temperature :0 ~ 40℃, humidity:0~95%( no condensation) | ||||
Noise | <60dB@1 meter | ||||
Altitude | <1000 meters, no derating, >1000 meters, derating 1% if every 100 meters increased | ||||
Cabinet Type | 4 Modules | 7 Modules | 12 Modules | ||
SIZE | |||||
System W x D x H (mm) | 600 x 890 x 1200 | 600 x 960x 1600 | 600 x 1010 x 2000 | ||
Module W x D x H (mm) | 440 x 690 x 86 ( 2U) | ||||
WEIGHT | |||||
System(kg) | 140 | 185 | 250 | 270 | |
Module(kg) | 25 |
APPLICATIONS: